Advanced Liquid Cooling Solutions for Modern Data Centers

Our expert team designs and implements custom cooling infrastructures that lower operational costs, increase compute density and support sustainability goals. Whether you’re managing massive AI workloads or retrofitting legacy facilities, our tailored cooling technologies help you maximize both performance and efficiency.

Cooling Technologies

Direct Liquid to Chip (DLC)

Direct Liquid to Chip Cooling cools processors where they get hottest. This method works better than air cooling and uses less power.

DLC uses cold plates attached to CPUs, GPUs, and memory. Coolant flows through these plates to pull heat away quickly. Benefits include:

  • Better Cooling: Keeps processors 20-25°C cooler than air systems
  • More Computing Power: Supports racks using over 80kW without slowdowns
  • Lower Energy Use: Cuts PUE by 30-50%, saving money and power
  • Works for AI & HPC: Handles the heat from power-hungry AI and research systems

We don’t stick with one brand. We pick the best parts for your needs. Our team helps with both new builds and upgrades to older data centers.

placeholder imag
placeholder imag

Rear Door Heat Exchangers (RDHx)

Rear Door Heat Exchangers catch hot air as it leaves your servers. These cooling units are mounted on the back of server racks and cool the air using liquid.

When servers push out hot air, the RDHx captures this heat and transfers it to coolant flowing through the unit. This setup offers many perks:

  • Cools High-Density Racks: Handles racks using 30-50kW without major changes to your building
  • Saves Energy: Reduces or removes the need for room air conditioners, lowering PUE by up to 30%
  • Saves Space: No need for hot/cold aisle setups, letting you fit more servers
  • Easy to Add: Works with your current data center without big changes

We offer both passive and active models to match your needs, heat loads, and space limits. This tech works great in mixed cooling setups for AI and high-performance systems.

Single Phase Immersion Cooling

Immersion cooling for data centers dunks servers in a special fluid that doesn’t conduct electricity. This method offers the best cooling for extreme computing needs.

Our single-phase systems keep the fluid in liquid form at all times. This creates a simple yet highly effective cooling setup:

  • Best Thermal Control: Keeps all parts at stable temperatures, handling over 100kW per rack
  • Lowest PUE: Reaches industry-leading PUE of 1.03–1.1 by removing fans and air conditioners
  • Longer Hardware Life: Steady temperatures and no dust or dirt mean fewer failures
  • More Computing Power: Compact tanks let you fit more computing power in less space

We provide complete immersion solutions, including tanks, fluid selection, heat exchangers, and building integration. Our team ensures everything works together for the best performance and reliability.

placeholder imag

Distribution & Control Systems

placeholder imag

Cooling Distribution Units (CDUs)

Cooling Distribution Units serve as the brain of your cooling system. They manage the flow between building cooling and IT cooling loops, keeping fluid at the right temperature, pressure, and flow rate.

Our CDUs deliver the precision needed for enterprise cooling:

  • Clean Separation: High-quality heat exchangers keep building water separate from IT cooling loops
  • Exact Temperature Control: Smart systems keep the coolant at ideal temperatures for your servers
  • Backup Systems: Built with extra parts to keep running even if something fails
  • Room to Grow: Modular designs let you start small and expand as needed

Our team makes sure your CDUs fit your heat loads, backup needs, and operating conditions.

Chillers & Dry Coolers

Heat rejection systems move heat from your IT equipment to the outside world. We use both chillers (refrigeration) and dry coolers (free cooling) to match your local climate.

Our team designs systems that balance performance, reliability, and energy use:

  • Climate-Smart Design: Systems that use the most free cooling based on your location
  • Free Cooling When Possible: Dry coolers use outside air to save energy when weather permits
  • Smart Switching: Controls that shift between free cooling and mechanical cooling as needed
  • Water Savings: Designs that use less water and improve water efficiency

We help you pick the right heat rejection system for your climate, workloads, and efficiency goals.

placeholder imag
placeholder imag

Pumping Systems

Reliable fluid movement forms the backbone of liquid cooling. Our pumping systems provide steady, controlled flow to remove heat from your computing systems.

Our pumps deliver the reliability needed for critical systems:

  • Backup Design: Multiple pumps ensure cooling continues even if one fails
  • Speed Control: Smart pumps adjust flow rates to match actual heat loads, saving energy
  • Energy Efficient: High-efficiency motors use less power
  • Smart Monitoring: Advanced sensors track performance and predict maintenance needs

Our fluid experts ensure your pumping system is properly sized and controlled for the best efficiency and reliability.

Integration & Management

CRAH/CRAC Integration

Mixed cooling systems that use both liquid and air need smart design to work well together. We specialize in connecting liquid cooling with your Computer Room Air Handlers (CRAH) or Air Conditioners (CRAC).

Our approach makes sure these different systems work as one:

  • Smart Load Sharing: Divides cooling tasks between liquid and air systems based on equipment needs
  • Better Airflow: Redesigns air paths to work with liquid cooling, cutting unneeded air handling
  • Energy Savings: Uses liquid cooling for hot spots, lowering the work for air systems and improving PUE
  • Step-by-Step Change: Allows gradual shift from air to liquid without disrupting operations

We help bridge old and new cooling systems, making the most of your current setup while enabling denser computing.

placeholder imag
placeholder imag

System Controls

Smart control systems coordinate all cooling technologies as one unified solution. Our advanced controls provide complete monitoring and optimization across your entire cooling setup.

Our control systems deliver the smarts needed for efficient operation:

  • One Control Panel: Single interface for all cooling systems, pumps, and heat rejection
  • Problem Prevention: AI-enhanced monitoring spots issues before they affect performance
  • Dynamic Adjustment: Auto-tunes cooling based on real-time IT workloads and conditions
  • Energy Savings: Constantly fine-tunes settings to use less power while maintaining cooling

We ensure your control systems deliver the precision and efficiency needed for today’s demanding computing.

The Triton Thermal Advantage

Triton Thermal provides complete cooling solutions designed just for your computing needs. We don’t push one brand – we find the best tech for your workloads, building limits, and business goals.

From first assessment through design, installation, and ongoing tuning, our expertise ensures your cooling delivers top performance, efficiency, and reliability for your most demanding computing tasks.